Fluke Price list FLUKE-1555

FLUKE-1555

Subscribe to get prices

Model: FLUKE-1555

Order No: 4977519

SKU: 10000028656601

Condition: New Sealed Under Guarantee

Size: 200.00 mm,200.00 mm,150.00 mm

Weight: 500.00g

Product Selection Engineer:Lixintao

In Stock

Brief Introduction

FLUKE-1555

Key features Quickly configure, start and stop tests on the 1555 remotely, a safe distance away from any operating, energized equipment, using Fluke Connect® and a smart phone Real time trending gives you easy-to-see visual cues, rather than hard to read, rapidly changing values Report creation using Fluke Connect desktop saves time and makes test results easier to understand Fluke Connect saves test results to the cloud for analysis and preventive maintenance Electrical Specifications The tester's accuracy is specified for one year after calibration at operating temperatures of 0°C to 35°C. For operating temperatures outside the range (-20°C to 0°C and 35°C to 50°C), add ±.25% per °C, except on the 20% bands add ±1% per °C. Insulation Resistance Measurement Test voltage (DC) 250 V Range < 250 kΩ,250 kΩ to 5 GΩ5 GΩ to 50 GΩ> 50 GΩ Accuracy (± reading) Unspecified5%20%Unspecified 500 V Range < 500 kΩ500 kΩ to 10 GΩ10 GΩ to 100 GΩ> 100 GΩ Accuracy (± reading) Unspecified5%20%Unspecified 1000 V Range < 1 MΩ1 MΩ to 20 GΩ20 GΩ to 200 GΩ> 200 GΩ Accuracy (± reading) Unspecified5%20%Unspecified 2500 V Range < 2.5 MΩ2.5 MΩ to 50 GΩ50 GΩ to 500 GΩ> 500 GΩ Accuracy (± reading) Unspecified5%20%Unspecified 5000 V Range < 5 MΩ5 MΩ to 100 GΩ100 GΩ to 1 TΩ> 1 TΩ Accuracy (± reading) Unspecified5%20%Unspecified 10000 V Range < 10 MΩ10 MΩ to 200 GΩ200 GΩ to 2 TΩ> 2 TΩ Accuracy (± reading) Unspecified5%20%Unspecified Bar graph range 0 to 1 TΩ (1550C) - 0 to 2 TΩ (1555) Insulation test voltage accuracy -0%, +10% at 1 mA load current Induced AC mains current rejection 2 mA maximum Charging rate for capacitive load 5 seconds per μF Discharge rate for capacitive load 1.5 s/μF Leakage current measurement Range 1 nA to 2 mA Accuracy ±(5% + 2 nA) Capacitance measurement Range 0.01 μF to 15.00 μF Accuracy ±(15% rdg + 0.03 μF) Timer Range 0 to 99 minutes Resolution setting 1 minute Resolution indication 1 second Live circuit warning Warning range 30 V to 660 V AC/DC, 50/60 Hz Voltage accuracy ±(15% + 2 V) Software specifications FlukeView Forms™ basic software requires a PC running Windows XP, Windows Vista , Windows 7 or Windows 8. General Specifications Display 75 x 105 mm Power 12 V lead-acid rechargeable battery, Yuasa NP2.8-12 Charger Input (AC) 85 V to 250 V AC 50/60 Hz 20 VA This Class II (double insulated) instrument is supplied with a Class 1 (grounded) power cord. The protective earth terminal (ground pin) is not connected internally. The extra pin is for added plug retention only. Dimensions 269 x 277 x 160 mm (10.6 x 10.9 x 6.3 in) Weight 3.7 kg (8.2 lb) Temperature (operating) -20°C to 50°C (-4°F to 122°F) Temperature (storage) -20°C to 65°C (-4°F to 149°F) Humidity 80% to 31°C decreasing linearly to 50% at 50°C Altitude 2000 m Enclosure sealing IP40 Input overload protection 1000 V AC Electromagnetic compatibility EN 61326 Safety compliance IEC 61010-1: Overvoltage category II, Pollution Degree 2.IEC 61010-2-030: Measurement 600V CAT IV / 1000V CAT IIIIEC 61557-1, IEC 61557-2 FLUKE1555

Description

FLUKE Instruments and Tools FLUKE-1555
Unsubscribe

Discount Code

Subscribe
Please check the item(s) you are interested in. (required)

Enter email to obtain information:

Verification code:

verify-code
USE : 0.012349843978882